2026.2 Self-Managed Release🔗
Update 2026-NOV-25🔗
General availability: Modelon Impact Self-Managed
This self-managed Modelon Impact 2026.2 release ships the Modelon Library Suite 2026.2 and Optimica Compiler Toolkit 1.70, and includes all UI improvements delivered in the 2026.1 updates from April through October 2026 (excluding AI agent).
Highlights🔗
- FMI 3.0 Co-Simulation export, with optional packaging of resource directories.
- Optimica Compiler Toolkit 1.70 with compiler improvements and fixes.
- Library imports become Released projects when imported through the Libraries tab.
- New icon editor enabled by default.
- Long simulations keep running for up to 8 hours.
- Plotting and log improvements: draggable plot headers, per-case colors in multi-experiment plots, and log downloads of any size.
- Better resilience to network interruptions.
Platform🔗
FMU export: FMI 3.0🔗
FMU export now supports FMI 3.0 in both Model Exchange and Co-simulation modes. Select the FMI version when you export.
Modelica Compiler (OCT 1.70)🔗
Improvements🔗
- Resource directories in FMUs: directories loaded with
loadResourcecan be packaged into the FMU with the newload_resource_directory_size_limitoption (bytes, a kb/mb/gb suffix, or -1 for any size). The limit applies per directory. The default is 0, which includes no directories and warns for each one omitted; the default will be raised in a future release. Files loaded into a constant are included whenload_resource_include_constantsis true. - Compilation time: total compile time is shown in the log at every log level.
- Euler solvers:
ExplicitEulerandImplicitEulernow store results at the specified Points or Interval, like other solvers (ncpin Python). - pathlib.Path support:
pymodelica,pyfmi,pyjmi,oct.diagnosticsandoct.steadystateacceptpathlib.Pathobjects.
The compiler also includes a number of bug fixes, including fixes for FMI 2.0 and 3.0 FMU export. See the OCT 1.70 release notes for details.
Modeling and analysis improvements🔗
Modeling🔗
- The new icon editor is enabled by default.
- Error messages now include line number references.
Plotting and analysis🔗
- The whole plot header can be dragged and selected, making plots easier to rearrange.
- Multi-experiment plots can assign a separate color to each case.
- Plotting or dropping variable nodes with more than 50 variables onto the canvas is now blocked.
Logs and simulation files🔗
- Simulation and compilation logs over 5 MB now show a download button instead of truncating.
- A warning appears for potentially large simulation files or log artifacts when
simulationLogLevelis INFO, VERBOSE or DEBUG, or whendynamic_diagnosticsis true.
Reliability🔗
- Long simulations keep running: the session stays active during a simulation so it can finish on its own. Simulations can run for up to 8 hours before they are cancelled.
- Network resilience: the UI handles network interruptions more smoothly, including on unstable connections.
Library import as Released projects🔗
- Importing a Modelica library or package as a compressed file (.mol or .zip) through the Libraries tab now converts it into a Released project. Name, version and dependencies are read from the Modelica annotations in
package.moorpackage.moc. - Importing a Modelon Impact project as a compressed .zip through the Libraries tab also converts it into a Released project. Previously, these appeared under Projects as Local projects.
Execution environment🔗
| Component | 2026.2 | 2026.1 |
|---|---|---|
| Optimica Compiler Toolkit | v1.70 | v1.66 |
| Modelica compliance | v3.4 | v3.4 |
| FMU compliance | v1, v2 (default), v3 (export only; simulation not supported) | v1, v2 (default) |
| Operating system | Ubuntu 22.04 | Ubuntu 22.04 |
| Python | 3.11 | 3.11 |
| C compiler | GCC 11.4, glibc 2.35 | GCC 11.4, glibc 2.35 |
Self-managed installations include only the latest execution environment.
Breaking changes🔗
None. See the OCT 1.70 release notes for all changes.
Bug fixes🔗
This release includes many bug fixes across modeling, experiments, plotting, simulation and workspace handling, improving stability and performance.
- Sessions created with an API key now end as soon as the key is deleted.
Libraries🔗
Modelon Library Suite 2026.2 focuses on two-phase tank and storage modeling, data center cooling, refrigerant-side heat exchanger detail and more robust initialization. Several libraries have breaking changes; see Breaking changes below.
Highlights🔗
- Data Center Library 3.0 (new in self-managed): full-system data center cooling models, including 1 MW and 7 MW reference systems, two-phase direct-to-chip racks, a chiller fidelity ladder, a wet cooling tower, vendor-specific CDU and CRAH records, calibration workflows and PUE/WUE metering.
- Two-phase tanks: tanks that change size, run dry or fill completely, and operate through the critical pressure.
- Flat-tube heat exchangers: per-channel refrigerant discretization and ports.
- Steady-state initialization: more robust at zero and reversing flow.
- Jet Propulsion Library returns to Modelon Impact due to strong customer demand.
- Buildings Library 14.0.0 and 13.0.1 are available.
Data Center Library 3.0 (new)🔗
This is the first self-managed release that includes the Data Center Library (DCL). DCL models the full cooling chain of a data center, from chips and racks through CDUs and CRAHs to chillers, economizers and cooling towers, so you can size equipment, compare cooling architectures and evaluate PUE and WUE. Version 3.0 includes everything released on Modelon Cloud as DCL 2.0 in June 2026, plus the 3.0 additions below.
Library structure
Top-level packages are Facility (racks, pods, CDUs, CRAHs), CoolingPlant (chillers, cooling towers, economizers, subsystems), Components (pumps, fans, pipes, valves, volumes, sensors, sources, weather), Routing, Controls, CalibrationWorkflows, Utilities and Examples. Facility models come in two fidelity tiers: Generic models use nominal design-point parameters, and Geometric models are geometry-based and calibratable.
Facility
- Racks: low-fidelity air, liquid and hybrid racks; a hybrid rack with rear-door heat exchanger; and new two-phase direct-to-chip racks (
TwoPhaseRack) with micro-channel cold plates and CPU/GPU-series and four-chip-parallel server variants. - Reduced-order cold plate:
AlgebraicChannelis a drop-in replacement forMicroChannel, with calibration held in a replaceable record. - IT load: racks, servers and pods take a replaceable
LoadProfilewith aQ_IToutput. Load tables hold the last value past their end by default;Periodicrepeats a daily profile. - Pods:
NetAiNetRowcombines liquid-cooled AI racks and air-cooled network racks in one row-level component. - CDUs: Generic Nominal and Geometric SetFlow and Pump models, with pre-calibrated vendor performance records.
- CRAHs: Generic Nominal and Geometric SetFlow and Fan models, plus vendor-specific models backed by eight datasheet records from Schneider Electric, Stulz and Vertiv.
Cooling plant
- Chillers: a fidelity ladder with
LowFidelity(Carnot reduced-order),IntermediateFidelity(empirical) andHighFidelity(vapor cycle) models. For air-cooled chillers, useIntermediateFidelity.AirCooled. - Cooling towers: dry tower and a new closed-circuit evaporative
WetTowerthat reports cumulative makeup water and wet-bulb approach. - Economizers: Generic (nominal) and Geometric (geometry-driven) water-side economizers, and a
CoolingPlantWithWSEsubsystem with an integrated dry tower. - Controls: chiller plant staging with bypass, configurable for any number of plants.
Weather and metering
- Weather: reads TMY3 hourly data (dry-bulb, relative humidity, wet-bulb, wind speed). Five locations are pre-loaded.
- EnergyDashboard: shows PUE (ISO/IEC 30134-2 Class 1), WUE (ISO/IEC 30134-9), cooling power per category, cumulative energy and hours per cooling mode.
Calibration workflows
Calibration workflows fit models to measured or reference data for cold plates, chillers and CRAHs, with calibrated example records. Geometric CDU, CRAH and rack models expose their calibration parameters at the top level.
Examples
- Reference systems:
DataCenter1MWandDataCenter7MWare full-system models of the Schneider Electric reference designs. The 7 MW model combines a high-temperature loop with a free-cooling chiller plant feeding six CDUs, a low-temperature loop feeding CRAHs, and six rows of AI and network racks. - System examples:
ChillerWithEconomizerSystem,ChillerStagingSystemand others, plus Demo test benches in each package.
Dependencies
DCL 3.0 requires the following libraries, all included in this release. Add them to the workspace in Workspace Management:
- Modelon Base Library 7.1
- Liquid Cooling Library 4.1
- Vapor Cycle Library 6.0
- Calibration Library 2.0
- Modelica Standard Library 4.1.0
Modelon Base 7.1🔗
- Time-varying tank dimensions let you model pistons, bellows and deforming tanks.
variableFluidHeightgives a moving fluid boundary on a fixed wall discretization. NonEquilibriumVolumesimulates boil-off to a dry tank and filling to a liquid-full tank.- Tanks can be compressed out of the two-phase region into supercritical and back.
- New
EpsNTUNominalbasedheat exchanger, parameterized from nominal duty and temperatures without geometry. - Helmholtz media converge near the critical point, and
CheckValvesupports closing events and leakage.
Air Conditioning 4.0🔗
- Flat-tube heat exchangers can split each pass into parallel channels (
n_segRefOrth) and optionally expose per-channel ports. - Refrigerant header dimensions are defined in the heat exchanger geometry record together with the core geometry.
- Steady-state initialization handles zero or reversing flow (
mdot_reg_init). - Robustness: inlet enthalpy filtering in
PhaseSeparator, an analytical Jacobian for the air heater, and fewer events fromLimiter.
Electrification 2.3🔗
- New
CRateTemperatureDependentBipolarbattery capacity model based on C-rate and temperature.
Energy Systems 2.1🔗
- New
DataCenterpackage with server, economizer and cooling tower models, plus two examples. ExcelTableReadergains a sheet name option,HeatSupplyComparisonis improved, and the medium inEconomicDispatchis corrected.
Vapor Cycle 6.0🔗
- Cryogenic hydrogen tanks can change volume, boil dry, fill liquid-full and pass the critical pressure. Three new examples show these cases.
- Robustness: hydrogen transport properties no longer overflow, and receiver and separator initialization is more robust.
Jet Propulsion 2.13🔗
- The Jet Propulsion Library returns to Modelon Impact due to strong customer demand.
Buildings Library🔗
Buildings Library 14.0.0 and 13.0.1 are available. Buildings 13.0.0, which was available with the 2025.May distribution, is removed from self-managed 2026.2.
Library versions🔗
| Library | 2026.2 | 2026.1 | 2025.2 |
|---|---|---|---|
| Air Conditioning / AirConditioningAdapters | 4.0 | 3.0 | 2.0 |
| Buildings | 14.0.0 and 13.0.1 | 12.1.1 | 12.1.1 |
| Data Center | 3.0 | 2.0 | – |
| Electrification | 2.3 | 2.2 | 2.1 |
| Energy Systems | 2.1 | 2.0 | 1.4 |
| Fuel Cell | 3.1 | 3.0 | 2.0 |
| Heat Exchanger | 6.0 | 5.0 | 4.0 |
| Hydraulics | 4.26 | 4.25 | 4.24 |
| Industry Examples | 1.10 | 1.9 | 1.8 |
| Jet Propulsion | 2.13 | – | – |
| Liquid Cooling | 4.1 | 4.0 | 3.0 |
| Modelica Standard Library | 4.1 | 4.1 | 4.0 |
| Modelon Base | 7.1 | 7.0 | 6.0 |
| Thermal Power | 4.1 | 4.0 | 3.0 |
| Vapor Cycle | 6.0 | 5.0 | 4.0 |
| Vehicle Dynamics | 4.10 | 4.9 | 4.8 |
Breaking changes🔗
- Modelon Base 7.1:
TankShapesgeometry quantities are now inputs/outputs and need manual updates (no conversion script).FlatWall_1duses its actual segment volume, which changes thermal inertia. - Air Conditioning 4.0: some initial solutions may change; reduce
mdot_reg_initto restore them.Limiterdefaults tostrict = true. - Data Center 3.0: requires a conversion script, with manual steps including plot scripts that use renamed summary fields. Some defaults changed and can alter results. See the Data Center 3.0 release notes for details.
- Thermal Power 4.1: deprecated packages, including
MicroGridandDistrictHeating, are removed. - Vapor Cycle 6.0:
ReducedGeomteryis renamedReducedGeometry, andRefrigerationSystenInitis renamedRefrigerationSystemInit. Tank models are affected by the Modelon Base tank changes.
2025.May library distribution
The 2025.May library distribution has been removed from Modelon Impact. The following library versions are therefore no longer available.
| Libraries | 2025.May |
|---|---|
| AirConditioning | 1.30.0 |
| AirConditioningAdapters | 1.30.0 |
| Electrification | 2.0.0 |
| EnergySystems | 1.3.0 |
| FuelCell | 1.21.0 |
| HeatExchanger | 3.0.0 |
| Hydraulics | 4.23.0 |
| IndustryExamples | 1.7.0 |
| LiquidCooling | 2.15.0 |
| Modelon | 5.0.0 |
| ThermalPower | 2.0.0 |
| VaporCycle | 3.0.0 |
| VehicleDynamics | 4.7.0 |
| Buildings | 12.0.0 and 13.0.0 |